OM2: Farm field in Osaka Metropolitan University

OM2 site photos

General site details

Site name Farm field in Osaka Metropolitan University
AsiaFlux site code OM2
LocationSakai, Osaka, Japan
Position 34°32'32.83"N, 135°30'29.62"E
Elevation30 m above sea level
Slope0 deg
Terrain typeFlat
Area0.31 ha
Fetch50 m
ClimateWarm temperature (Cfa)
Mean annual air temperature15.6℃
Mean annual precipitation1206.9 mm
Vegetation typeWeed grassed
Dominant Species (Overstory)-
Dominant Species (Understory)Paspalum dilatatum, Setaria viridis, Eleusine indica, Bromus japonicus, Kyllinga brevifolia, Cyperus polystachyos, Juncus decipiens, Commelina communis, Solidago canadensis, Bidens Pilosa, Lactuca indica, Vicia villosa, Runmex japonicus, Persicaria longiseta, Ranunculus cantoniensis, Achyranthes bidentata, Oenanthe javanica
Canopy heightSeveral tens of centimeters
AgeLess than one year
LAI0 ~ 5
Soil typepseudo-gray soil

Observation

Eddy Covariance method (CO2)

SystemOpen-path eddy covariance
Wind speedSonic anemometer (81000RE, R. M. Young)
Air temperatureSonic anemometer (81000RE, R. M. Young)
Water vaporOpen-path CO2/H2O analyzer (LI-7500, Li-Cor)
CO2Open-path CO2/H2O analyzer (LI-7500, Li-Cor)
Measurement height1.65 m
Sampling frequency10 Hz
Averaging time30 minutes
Data loggerCR1000 (Campbell Scientific Inc.)
Data storageCF card
Original dataRaw data

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation (incoming) 1 m Radiometer (SR05-A1, Hukseflux)
Global solar radiation (outgoing) 1 m Quantum sensor (ML-01, EKO)
Long-wave radiation (incoming) - -
Long-wave radiation (outgoing) - -
Net radiation 1 m Net Radiometer (NR LITE2, Kipp&Zonen)
PPFD (incoming) - -
PPFD (outgoing) - -
Direct/diffuse radiation - -
Direct/diffuse PPFD - -
Air temperature 1.5 m Platinum resistance thermometer and capacitive (HMP50, Vaisala)
Humidity 1.5 m Platinum resistance thermometer and capacitive (HMP50, Vaisala)
Soil temperature 0, 0.05, 0.1, 0.2, 0.3, 0.4 m Thermocouples
Soil heat flux 0.05 m Heat flux plate (HFP01SC, Hukseflux)
Soil water content 0.05, 0.1, 0.2 m TDR sensor (CS616, Campbell Scientific Inc.)
Wind speed 1.65 m Sonic anemometer (81000RE, R. M. Young)
Wind direction 1.65 m Sonic anemometer (81000RE, R. M. Young)
Barometric pressure - -
Precipitation - -
CO2 concentration 1.65 m Open-path CO2/H2O analyzer (LI-7500, Li-Cor)
Transmitted shortwave radiation 0 m Quantum sensor (ML-01, EKO)
Canopy temperature 1 m Radiation thermometer (IT-405N, Horiba)

Other

Phenology Phenological Camera (TLC2000, Brinno)
LAI Twice a month using a plant canopy analyzer (LAI-2000)

Observation Period and Data Availability

Measurement PeriodApril 2022 to present
Measurement FrequencyContinuous
Data Availability-

Contact

Masahito Ueyama (mueyama[at]omu.ac.jp)
Osaka Metropolitan University
Graduate School of Agriculture
1-1 Gakuencho, Naka-ku, Sakai, Osaka 599-8531, JAPAN
Phone: +81-72-254-9432

Infrastructure

Pole tower, Electrical power (AC)

Calibration Information

Open-path analyzers were calibrated approximately twice a year with standard CO2 gases a dew point generator (LI610, LI-COR) .