OM1: B11 building in Osaka Metropolitan University

OM1 site photos

General site details

Site nameB11 building in Osaka Metropolitan University
AsiaFlux site codeOM1
LocationSakai, Osaka, Japan
Position34°32'49.84"N, 135°30'10.30"E
Elevation27 m above sea level
Slope0 degree
Terrain typeFlat
Area-
Fetch150 m
ClimateWarm temperature (Cfa)
Mean annual air temperature15.6 ℃
Mean annual precipitation1206.9 mm
Vegetation typeRoadside trees (Deciduous broad leaf trees)
Dominant Species (Overstory)-
Dominant Species (Understory)-
Canopy height13.1 ± 2.9 m
Age-
LAI-
Soil typeConcrete and Asphalt

Observation

Eddy Covariance method (CO2)

SystemOpen-path eddy covariance
Wind speedSonic anemometer (Windmaster, Gill), until April, 2021 Sonic anemometer (CSAT3, Campbell Scientific Inc.), present
Air temperatureSonic anemometer (Windmaster, Gill), until April, 2021 Sonic anemometer (CSAT3, Campbell Scientific Inc.), present
Water vaporOpen-path CO2/H2O analyzer (LI-7500, Li-Cor), until April,2021 Open-path CO2/H2O analyzer (EC150, Campbell Scientific Inc.), present
CO2Open-path CO2/H2O analyzer (LI-7500, Li-Cor), until April,2021 Open-path CO2/H2O analyzer (EC150, Campbell Scientific Inc.), present
Measurement height16.2 m
Sampling frequency10 Hz
Averaging time30 minutes
Data loggerCR1000X (Campbell Scientific Inc.)
Data storagemicroSD card
Original dataRaw data

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation (incoming) 0.9 m above roof 4 component net radiometer (MR-40, Eko, Japan) Quantum sensor (ML-01, EKO)
Global solar radiation (outgoing) 0.9 m above roof 4 component net radiometer (MR-40, Eko, Japan) Quantum sensor (ML-01, EKO)
Long-wave radiation (incoming) 0.9 m above roof 4 component net radiometer (MR-40, Eko, Japan)
Long-wave radiation (outgoing) 0.9 m above roof 4 component net radiometer (MR-40, Eko, Japan)
Net radiation 0.9 m above roof Net Radiometer (NR LITE2, Kipp&Zonen)
PPFD (incoming) - -
PPFD (outgoing) - -
Direct/diffuse radiation - -
Direct/diffuse PPFD - -
Air temperature 0.8 m above roof Platinum resistance thermometer and capacitive (HMP60, Vaisala)
Humidity 0.8 m above roof Platinum resistance thermometer and capacitive (HMP60, Vaisala)
Soil temperature - -
Soil heat flux 0 cm above roof 0 cm above roof Heat flux plate (TEC-3105, Kyohritsu,Japan) Heat flux plate (HFP01-10, Hukseflux)
Soil water content 0~30 cm in rooftop gardening TDR sensor (CS616,Campbell Scientific Inc.)
Wind speed 1) 16.2 m a.g.l <br />2) 16.2 m a.g.l <br />3) 16 m a 1) Sonic anemometer (Windmaster, Gill), until April, 2021 <br />2) Sonic anemometer (CSAT3, Campbell Scientific Inc.), present <br />3) Vane anemometer (5103, R.M. Young)
Wind direction 1) 16.2 m a.g.l <br />2) 16.2 m a.g.l <br />3) 16 m a 1) Sonic anemometer (Windmaster, Gill), until April, 2021 <br />2) Sonic anemometer (CSAT3, Campbell Scientific Inc.), present <br />3) Vane anemometer (5103, R.M. Young)
Barometric pressure 16.2 m a.g.l Barometer (PTB110, Vaisala) Barometer (LI-7700, Li-Cor)
Precipitation 0 cm above roof Tipping-bucket raingauge (WBO015, Nakase, Japan)
CO2 concentration 16.2 m a.g.l Open-path CO2/H2O analyzer (LI-7500, Li-Cor), until April, 2021 Open-path CO2/H2O analyzer (EC150, Campbell Scientific Inc.), present
CO2 concentration 22.5 m a.g.l Closed-path CO2/H2O analyzer (LI-850, Li-Cor)
Surface temperature 18.0 m a.g.l Radiation thermometer (IT-405N, Horiba)
Roof temperature 0 cm above roof Thermocouple
CH4 concentration 16.2 m a.g.l Open-path CH4 analyzer (LI-7700, Li-Cor)
Ultraviolet radiation 0.9 m above roof Quantum sensor (CAP-SU-200-SS,Apogee)
CO concentration 16.2 m a.g.l Closed-path CO analyzer (Los Gatos Research)

Fluxes of non-CO2 gases

Gas CH<sub>4</sub>
Method Eddy covariance method
Measurement height 16.2 m
Data logger CR1000X (Campbell Scientific Inc.)
Data storage microSD Card

Other

Phenology Phenological Camera (Garden watch camera)

Observation Period and Data Availability

Measurement PeriodOctober 2014 to present
Measurement FrequencyContinuous
Data Availability-

Contact

Masahito Ueyama (mueyama[at]omu.ac.jp)
Osaka Metropolitan University
Graduate School of Agriculture
1-1 Gakuencho, Naka-ku, Sakai, Osaka 599-8531, JAPAN
Phone: +81-72-254-9432
https://www.omu.ac.jp/agri/ecolmet/ueyama/research02/index.html

Infrastructure

Pole tower, Electrical power (AC)

Research Fund

JSPS KAKENHI (18H03362)

Calibration Information

Open-path analyzer were calibrated approximately once a year with standard CO2 gases and a dew point generator (LI610, LI-COR)

Publication

Ueyama, M., Taguchi, A., Takano, T., 2021. Water vapor emissions from urban landscapes in Sakai, Japan. Journal of Hydrology, 598, 126384.

Takano, T., Ueyama, M., 2021. Spatial variations in daytime methane and carbon dioxide emissions in two urban landscapes, Sakai, Japan. Urban Climate, 36, 100798.