| Observation items |
Levels/Depth |
Instrument |
| Global solar radiation(incoming) |
2.5 m |
4 component net radiometer, CNR1 (Kipp&Zonen, The Netherlands) (August 1999 - April 2009). 4 component net radiometer, MR-40 (Eko, Tokyo,Japan) (May 2009 - present). |
| Global solar radiation (outgoing) |
2.35 m |
4 component net radiometer, CNR1 (Kipp&Zonen, The Netherlands) (August 1999 - April 2009). 4 component net radiometer, MR-40 (Eko, Tokyo,Japan) (May 2009 - present). |
| Long-wave radiation(incoming) |
2.35 m |
4 component net radiometer, CNR1 (Kipp&Zonen, The Netherlands) (August 1999 - April 2009). 4 component net radiometer, MR-40 (Eko, Tokyo,Japan) (May 2009 - present). |
| Long-wave radiation(outgoing) |
2.35 m |
4 component net radiometer, CNR1 (Kipp&Zonen, The Netherlands) (August 1999 - April 2009). 4 component net radiometer, MR-40 (Eko, Tokyo,Japan) (May 2009 - present). |
| Net radiation |
2.35 m |
4 component net radiometer, CNR1 (Kipp&Zonen, The Netherlands) (August 1999 - April 2009). 4 component net radiometer, MR-40 (Eko, Tokyo,Japan) (May 2009 - present). |
| PPFD (incoming) |
2.35 m |
4 component net radiometer, CNR1 (Kipp&Zonen, The Netherlands) (August 1999 - April 2009). 4 component net radiometer, MR-40 (Eko, Tokyo,Japan) (May 2009 - present). |
| PPFD (outgoing) |
2.35 m |
4 component net radiometer, CNR1 (Kipp&Zonen, The Netherlands) (August 1999 - April 2009). 4 component net radiometer, MR-40 (Eko, Tokyo,Japan) (May 2009 - present). |
| Direct / diffuse radiation |
- |
|
| Direct / diffuse PPFD |
- |
Quantum sensor, LI190SL (LI-COR) equipped with a shadow blade (Eko) (2005-2006). Quantum sensor, LI190SL (LI-COR) equipped with a rotating shadow blade PRB-100 (Prede, Tokyo, Japan) (July 2009 - present). |
| Air temperature |
3.85 m |
Platinum resistance thermometer (100 ohm) equipped with a home-made ventilator (August 1999 - 15 November 2000). Platinum resistance thermometer, HMP45A (Vaisala, Helsinki, Finland) equipped with a home-made ventilator (16 November 2000 - present). |
| Humidity |
3.85 m |
Wet-bulb temperature was measured with a platinum resistance thermometer (100 ohm) equipped with a home-made ventilator (August 1999 - 15 November 2000). Relative humidity was measured with a capacitive moisture sensor, HMP45A (Vaisala) equipped with a home-made ventilator (16 November 2000 - present). |
| Soil temperature |
-1, -5, -10, -20, -40 cm |
T-type thermocouple, hand-made |
| Soil heat flux |
1 cm below the soil surface |
Thermopile-type heat flux plate, MF-81 (Eko) (August 1999 - April 2008). Thermopile-type heat flux plate, MF-180M (Eko) (May 2008 - present). |
| Soil water content |
0-15 cm below the ground (April 2000 - April 2002). 0-2.5 cm, 0-5 cm, 0-10 cm, 0-20 cm and 0-30cm below the ground (May 2002 - present). |
Soil moisture probe, CS-615 (Campbell Scientific Inc., Logan, UT, USA) (April 2000 - April 2002).Time-domain reflectometory, TDR-100 (Campbell) (May 2002-present) |
| Wind speed |
3.75, 2.55, 1.95,1.35, 0.75 m |
The measurement heights were changed with rice growth. Cup anemometer, AF-750 (Makino, Tokyo, Japan) (August 1999 - April 2011). |
| Wind direction |
4.4 m |
Wind vane, VF016 (Makino) (August 1999 - April 2011) |
| Barometric pressure |
1.5 m |
Capacitive pressure transducer, PTA427 (Vaisala)(August 1999 - March 2008). Capacitive pressure transducer, PTB210 (Vaisala)(April 2008 - present). |
| Precipitation |
- |
Bucket-type rain gauge (TE525MM, Texas Electronics) |
| CO2 concentration |
3.85 m and 1.25 m (August 1999- September 2003. The measurement heights were changed with rice growth.) 3.8 m and several lower heights (May 2004 - present). |
Non-dispersive infrared gas analyzer, ZFU (Fuji Electric, Tokyo, Japan) (August 1999 - September 2003). Non-dispersive infrared gas analyzer, LI-6262 (LI-COR) (May 2004 - present) |
| Water depth |
- |
Sonic-type displacement sensor, UD-310 (Keyence,Osaka, Japan) |