KCR: Kon Chu Rang forest

KCR site photos

General site details

Site nameKon Chu Rang forest
AsiaFlux site codeKCR
LocationKon Chu Rang Nature Reserve Son Lang village, K’Bang district, Gia Lai province
Position14°29'58.9"N 108°32'43.9"E
Elevation1051 m above sea level
Slope< 3°
Terrain typePlateau
AreaExtensive
Fetch375 m (90%), 140 m (peak)
ClimateAw, Tropical savanna with dry winter
Mean annual air temperature20.0 (2022-2023) °С
Mean annual precipitation2611 mm (2022--2023)
Vegetation typeMid-mountain plydominant high forest
Dominant Species (Overstory)Protium serratum (Burseraceae), Endospermum chinensis (Euphorbiaceae), Dialium cochinchinensis (Fabaceae), Magnolia praecalva (Magnoliaceae), Choerospondias axillaris (Anacardiaceae), Dacricarpus imbricatus, Dacrydium ellatum (Podocarpaceae). Middle canopy: Polyosma blaensis (Escalloniaceae), Quercus fleuryi (Fagaceae), Rehderodendron indochinensis (Styracaceae), Adinandra caudata (Theaceae)
Dominant Species (Understory)Popowia cambodiana (Annonaceae), Lasianthus spp., Ixora sp., (Rubiaceae), Tabernaemontana sp. (Apocynaceae), Ardisia sp. (Primulaceae)
Canopy height28 m (max. 33 m)
AgePrimary forest
LAINot measured
Soil typeFerralitic soil (orthic acrisols, 7.5YR 4/4 -- 10YR 3/3 Munsell scale)

Observation

Eddy Covariance method (CO2)

SystemEnclosed-path system (CO2 flux, latent heat flux)
Wind speedThree-dimensional sonic anemometer (WindMaster Pro, Gill inatruments)
Air temperatureThree-dimensional sonic anemometer (WindMaster Pro, Gill inatruments)
Water vaporEnclosed-path CO2/H2O analyzer (LI-7200, LI-COR)
CO2Enclosed-path CO2/H2O analyzer (LI-7200, LI-COR)
Measurement height50 m
Sampling frequency10 Hz
Averaging time30 min
Data loggerLI-7550 Analyzer Interface Unit / SmartFlux2
Data storageUSB drive, FTP upload
Original dataRaw data

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation (incoming) 50 m Photodiode pyranometer (LI-200R, LI-COR)
Net radiation 50 m 1-component net radiometer (NRLite, K&Z)
PPFD (incoming) 52 m Photodiode quantuum sensor (LI-190R, LI-COR)
Air temperature 45, 2 m Platinum resistance thermometer and capacitive Hygrometer (HMP155, Vaisala)
Humidity 45, 2 m Platinum resistance thermometer and capacitive Hygrometer (HMP155, Vaisala)
Soil temperature 8 cm (six points) Thermistor (7900-180 temperature probe, LI-COR); HydraProbeII (Stevens)
Soil heat flux 0.05 m Heat flux plate: PHF-01, REBS
Soil water content 0.08 m Coaxial Impedance Dielectric Reflectometry sensor (HydraProbeII, Stevens)
Wind speed 50 m Sonic anemometer (WindMaster Pro, Gill inatruments)
Wind direction 50 m Sonic anemometer (WindMaster Pro, Gill inatruments)
Barometric pressure 50 m Analyser interface unit built-in barometer (LI-7550, LI-COR)
Precipitation 50 m Tipping-bucket rain gauge (TE-525M, Texas Instruments)
CO2 concentration 50 m Enclosed-path CO2/H2O analyzer (LI-7200, LI-COR)

Observation Period and Data Availability

Measurement PeriodJuly 2022 -- present
Measurement FrequencyContinuous
Data Availability

Contact

[PI – VN side]
Dinh Ba Duy (duydb.vrtc[at]gmail.com)
Joint Vietnam-Russia Tropical Science and Technology Research Center
Institute of Tropical Ecology
63 Nguyen Van Huyen str., Nghia Do ward, Hanoi city, 100000, Vietnam
Tel: (+8424) 38363906

[PI – RU side]
Julia Kurbatova (kurbatova.j[at]gmail.com)
A.N. Severtsov Institute of Ecology and Evolution of the Russian Academy of Sciences
V.N. Sukachev Laboratory of Biogeocenology Leninsky Prospekt, 33 Moscow, 119071, Russia
Tel:+7(903)710-3744

[Fluxes, Meteorology, Instrumentation]
Vitaly Avilov (vitavilov[at]gmail.com) [Fluxes, Meteorology, Instrumentation]
A.N. Severtsov Institute of Ecology and Evolution of the Russian Academy of Sciences
V.N. Sukachev Laboratory of Biogeocenology Leninsky Prospekt, 33 Moscow, 119071, Russia
Tel:+7(903)262-6295

Dinh Vu Anh Tu (anhtu2893[at]gmail.com)

Natalia Myslitskaia (myslitskaya[at]gmail.com)

Fedor Amirov (amirow-fedor[at]mail.ru)

Ngo Thanh Dat (datdotq95[at]gmail.com)

Infrastructure

Tower (49.9m), ancillary building (2x4m), solar power, 2G cellular communication, accomodation (4 km away)

Research Fund

Joint Vietnam-Russia Tropical Science and Technology Research Center

Calibration Information

● LI-7200 – annual CO2/H2O zero using molecular sieve scrubber (31022 Zero Air Generator, Campbell Scientific), annual CO2 span – using reference gas (616ppm CO2 in air)
● HMP155 – annual 2-point humidity adjustment by ~35% and ~85% points using reference capacitive hygrometer DV2-TS (Microfor, Russia), 1-point temperature adjustment using reference platinum thermometer PTSV-6-Km-3 (Microfor, Russia)
● TE525M – annual field check using Rain Gauge Calibrator (52260, RM Young), 500ml, .50 orifice
● LI200R – annual field matching with reference pyranometer (SR30D2, Hukseflux)
● LI190R – annual field matching with reference quantum sensor (LI190R, LI-COR)
● LI7550 integrated barometer – annual comparison with reference absolute pressure sensor PDE-020I-DA (Elemer, Russia)