KBY: Kobayashi

KBY site photos

General site details

Site nameKobayashi
AsiaFlux site code KBY
LocationKobayashi, Miyazaki, Japan
Position 31º 58' N, 130º 56' E
Elevation298 to 301 m above sea level
Slope1.0 degree
Terrain typeN/A
Area[Manure] 6ha, [Fertilizer] 6.5ha
Fetch80 to 240 m
ClimateWarm temperate (Humid subtropical climates [Cfa])
Mean annual air temperature16.2 degree C
Mean annual precipitation2800 mm
Vegetation typeHay meadow (Chemical and Manure plots)
Dominant Species (Overstory)Southern crabgrass (Digitaria adscendens (H.B.K) Henr.), Japanese millet (Echinochloa utilis Ohwi et Yabuno), Itarian ryegrass (Lolium multiflorum Lam.), Orchardgrass (Dactylis glomerata L.), Tall fescue (Festuca arundinacea Schreb.), Bahiagrass (Paspalum notatum Flugge)
Dominant Species (Understory) N/A
Canopy height Maximum 1.5 m
Age10 years in 2010
LAIN/A
Soil typeVolcanogenous andosol

Observation

Eddy Covariance method (CO2)

Systemopen-path system
Wind speedSonic anemometer-thermometer (CSAT3, Campbell)
Air temperature Sonic anemometer-thermometer (CSAT3, Campbell)
Water vaporNDIR (LI-7500, LICOR, USA)
CO2 NDIR (LI-7500, LICOR, USA)
Measurement height 2.51 m at mature plot, 2.42 m at fertilizer plot
Sampling frequency10 Hz
Averaging time 30 min
Data loggerCR23X-4M (Campbell, USA)
Data storageHD, DVD
Original dataRaw data

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation(incoming -
Global solar radiation (outgoing) -
Long-wave radiation(incoming) -
Long-wave radiation(outgoing) -
Net radiation -
PPFD (incoming) 2 m Quantum sensor (LI-190SA, LI-COR, USA)
PPFD (outgoing) 2 m Quantum sensor (LI-190SA, LI-COR, USA)
Direct / diffuse radiation -
Direct / diffuse PPFD -
Air temperature 2.5 m Ventilated Pt resistance thermometer (HMP-45A, VAISALA) at mature field
Humidity 2.5 m Capacitive hygrometer (HMP-45A, VAISALA)
Soil temperature -0.05, -0.1, -0.3 m T-type thermocouple (T-soil4, MeiwaShoji)
Soil heat flux -
Soil water content -0.05, -0.1, -0.3 m (EC20, DECAGON)
Wind speed 2.5 m Sonic anemometer-thermometer (CSAT3, Campbell)
Wind direction 2.5 m Sonic anemometer-thermometer (CSAT3, Campbell)
Barometric pressure -
Precipitation -
CO2 concentration -

Other

Soil respiration Static closed chamber
Photosynthesis -
Ecological investigation -
Methane (CH4) Static closed chamber (biweekly) 2004-2009
Nitrous oxide (NO2) Static closed chamber (biweekly) 2004-2009

Observation Period and Data Availability

Measurement Periodfrom August 2004 to March 2009
Measurement Frequency Continuous
Data Availability N/A

Contact

Osamu KAWAMURA (kawamura [at] cc.miyazaki-u.ac.jp) Mitsuhiro NIIMI (mitsu-n [at] cc.miyazaki-u.ac.jp) University of MiyazakiGakuen-kibanadai-nishi-1-1, Miyazaki, 889-2192, Japan TEL&FAX : +81-985-58-7259

Takahiro TERADO (t0terado [at] nlbc.go.jp) Hosono-5157-29, Kobayashi, Miyazaki, 886-0004, Japan TEL : +81-984-23-3500 FAX : +81-984-23-0953

Yasuyuki ISHII (yishii [at] cc.miyazaki-u.ac.jp)

Infrastructure

Tower (2.5m), Electrical power (100V AC)

Research Fund

Research grants from Racing and Livestock Association organized by Japan Grassland Agriculture & Forage Seed Association

Calibration Information

Open-path analyzers were calibrated once in a year with standard CO2 gases and a dew point generator (LI610, LI-COR).