HPK: Haenam Paddy-field

HPK site photos

General site details

Site nameHaenam Paddy-field
AsiaFlux site codeHPK
LocationHaenam-gun, Jeollanamdo (Southwestern end of Korea Peninsular), Republic of Korea
Position34° 28'38" N, 126° 28'52" E
Elevation3 m a.s.l.
Slope
Terrain typeFlat
Area-
Fetch~ 200m
ClimateCfa
Mean annual air temperature-
Mean annual precipitation-
Vegetation typeRice paddy
Dominant Species (Overstory)Oryza sativa
Dominant Species (Understory)-
Canopy height~ 1m
AgeAnnual plant
LAI-
Soil type-
URLhttp://www.ncam.kr/page/koflux/database/index.php

Observation

Eddy Covariance method (CO2)

SystemOpen path (CO2 flux, latent heat flux, CH4 flux)
Wind speed3D sonic anemometer (CSAT3)
Air temperature3D sonic anemometer (CSAT3)
Water vaporOpen path infrared gas analyzer (LI-7500)
CO2Open path infrared gas analyzer (LI-7500)
Measurement height
Sampling frequency20 Hz
Averaging time30 min.
Data loggerCR3000, CSI
Data storageHD
Original dataRaw data (and statistics)
CH4Open path CH4 analyzer (LI-7700, Li-Cor)

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation (incoming) 3.5 m Net radiometer (CNR4, Kipp & Zonen, Netherlands)
Global solar radiation (outgoing) 3.5 m Net radiometer (CNR4)
Long-wave radiation (incoming) 3.5 m Net radiometer (CNR4)
Long-wave radiation (outgoing) 3.5 m Net radiometer (CNR4)
Net radiation 3.5 m Net radiometer (CNR4)
PPFD (incoming) - -
PPFD (outgoing) - -
Direct/diffuse radiation - -
Direct/diffuse PPFD - -
Air temperature 3.5 m Temperature and RH probe (HMP155, Vaisala, Finland)
Humidity 3.5 m Temperature and RH probe (HMP155, Vaisala, Finland)
Soil temperature 0 ~ -0.1 m Multiparameter smart sensor (CS655, Campbell Sci., Inc., USA)
Soil heat flux -0.1 m Heat flux plate (HFP01, Hukseflux Thermal Sensors B.V., Netherlands)
Soil water content 0 ~ -0.1 m Multiparameter smart sensor(CS655)
Wind speed 3.5 m 3D sonic anemometer (CSAT3, CSI)
Wind direction 3.5 m 3D sonic anemometer (CSAT3, CSI)
Barometric pressure 3.5 m Open path infrared gas analyzer (LI7500, Li-Cor)
Precipitation 3.5 m Tipping Bucket (WDR-205, Wedaen, Korea)
Water depth Ground Water level gauge (BYL-EV250, Korea)
Water temperature Ground (Water) Thermocouple probe (TCAV, CSI)

Fluxes of non-CO2 gases

Gas CH4
Method Open path CH4 analyzer (LI-7700, Li-Cor)
Measurement height 3.5 m
Data logger Analyzer interface unit (LI-7550, Li-Cor)
Data storage Raw data (and statistics)

Other

Soil respiration -
Photosynthesis -
Ecological Investigation -

Observation Period and Data Availability

Measurement PeriodFrom June 2016 to present
Measurement FrequencyContinuous
Data AvailabilityN/A

Contact

Joon Kim (joon[at]snu.ac.kr)
Department of Landscape Architecture and Rural Systems Engineering,
Seoul National University
Complex Systems Science Laboratory, Bld.36/Rm.108, Seoul National
University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea
Phone: +82-2-880-4663 Fax: +82-2-871-0230

Minseok Kang (ms-kang[at]ncam.kr)
National Center for Agro-Meteorology
Bld.36/Rm.109, Seoul National University, 1 Gwanak-ro, Gwanak-gu,
Seoul 08826, Korea
Phone: +82-2-871-0232 Fax: +82-2-871-0230

Infrastructure

Tower, Electrical power (AC)

Research Fund

Korea Meteorological Administration Research and Development Program under Grant KMIPA 2015-2023 and Weather Information Service Engine (WISE) project, KMIPA-2012-0001-2

Calibration Information

Open path gas analyzer was calibrated approximately every 6 months with standard CO2 gases and a dew point generator (LI610, Li-Cor). Other micrometeorological instruments are being calibrated approx. once in every 2 year.

Publication

N/A