HDF: Hariphunchai Dry Dipterocarp Forest
General site details
| Site name | Hariphunchai Dry Dipterocarp Forest |
|---|---|
| AsiaFlux site code | HDF |
| Location | Chiang Mai University “Hariphunchai” Centre, 205 Sri Boaban Sub-district, Muang Lamphun District, Lamphun Province 51000, Thailand |
| Position | 18° 32′ 25.9″ N, 99° 07′ 01.2″ E (WGS 84; GPS: GARMIN GPSMAP 66s and map) |
| Elevation | 364 m above mean sea level |
| Slope | - |
| Terrain type | Moderate slope |
| Area | 721 ha |
| Fetch | 736 m |
| Climate | Tropical savanna climate (dry winter, Aw) |
| Mean annual air temperature | 26.1 °C (1981–2010, reported by TMD station) |
| Mean annual precipitation | 962.4 mm (1981–2010, reported by TMD station) |
| Vegetation type | Dry dipterocarp forest |
| Dominant Species (Overstory) | Shorea obtusa Wall. ex Blume Shorea siamensis Miq. Canarium subultum Guillaumin. Gluta usitata (Wall.) DingHou Pterocarpus macrocarpus Kurz. (Burmese rosewood) |
| Dominant Species (Understory) | - |
| Canopy height | 9 m |
| Age | In progress (reported May 2025) |
| LAI | In progress (reported May 2025) |
| Soil type | Sandy loam |
Observation
Eddy Covariance method (CO2)
| System | Open-path system (CO2 flux, latent heat flux) |
|---|---|
| Wind speed | WindMaster Pro 3-Axis Ultrasonic Anemometer, Gill |
| Air temperature | WindMaster Pro 3-Axis Ultrasonic Anemometer, Gill |
| Water vapor | Open Path CO2/H2O Gas Analyzer (LI-7500DS, LI-COR) |
| CO2 | Open Path CO2/H2O Gas Analyzer (LI-7500DS, LI-COR) |
| Measurement height | 32.5 m |
| Sampling frequency | 10 Hz |
| Averaging time | 30 min |
| Data logger | SmartFlux3, LI-COR, USA |
| Data storage | microSD card |
| Original data | Raw data |
Meteorology
| Observation items | Levels/Depth | Instrument |
|---|---|---|
| Global solar radiation (incoming) | 32 m | Hukseflux NR01 Net Radiometer |
| Global solar radiation (outgoing) | 32 m | Hukseflux NR01 Net Radiometer |
| Long-wave radiation (incoming) | 32 m | Hukseflux NR01 Net Radiometer |
| Long-wave radiation (outgoing) | 32 m | Hukseflux NR01 Net Radiometer |
| Net radiation | 32 m | Hukseflux NR01 Net Radiometer |
| PPFD (incoming) | 32 m | LI-190R Quantum Sensor, LI-COR |
| Air temperature | 32 m | Humidity and Air Temperature Probe, Vaisala HMP155 |
| Humidity | 32 m | Humidity and Air Temperature Probe, Vaisala HMP155 |
| Soil temperature | -16 cm (3 points) | Stevens Hydra Probe II |
| Soil water content | -16 cm (3 points) | Stevens Hydra Probe II |
| Soil heat flux | -8 cm (3 points) | Soil Heat Flux Plate |
| Wind speed | 32.5 m | WindMaster Pro 3-Axis Ultrasonic Anemometer, Gill |
| Wind direction | 32.5 m | WindMaster Pro 3-Axis Ultrasonic Anemometer, Gill |
| Precipitation | 32 m | TR-525-M10 Tipping Bucket Rain Gauge with 9.66 in. Orifice, Texas Electronics, USA |
Soil respiration
| Measurement method | Open-flow (OF) IRGA chamber method (Steady state flow-through method) |
| Measuring system | closed system |
| IRGA | LI-6800 |
| Flow control | circulation pump from chamber |
| Chamber type | Open-flow (OF) |
| Chamber size | 4244.1 cm³ (spherical cap chamber) |
| Number of chambers | 1 |
| Measuring intervals | Once per month (discontinuous) |
| Original data (Raw data or statistics) | Raw data |
Fluxes of non-CO2 gases
| Gas | CH₄ |
| Method | Eddy covariance method (Open Path CH₄ Analyzer, LI-7700, LI-COR) |
| Measurement height | 32.5 m |
| Sampling frequency | 10 Hz |
| Averaging time | 30 min |
| Data logger | SmartFlux® 3 System, LI-COR |
| Data storage | Wireless data transmission, USB drive |
| Original data (Raw data or statistics) | Raw data |
Other
| Ecological investigation | Tree heights, stand density, diameter, biomass, and tree identification (2023–2024) |
Observation Period and Data Availability
| Measurement Period | February 2025–present (reported May 2025) |
|---|---|
| Measurement Frequency | Continuous |
| Data Availability | Data processing and publication in progress (reported May 2025) |
Contact
Dr. Montri Sanwangsri (montri.s[at]cmu.ac.th), (montriseen[at]gmail.com)
Mana Panya (manapanya[at]gmail.com) — Flux and micrometeorology
Dr. Panida Kachina (panida.k[at]cmu.ac.th) — Ecological survey
Dr. Nipon Mawan (nipon.m[at]cmu.ac.th) — Soil respiration
Agriculture and Forestry Climate Change Research Center (AFCC), Department of Highland Agriculture and Natural Resources, Faculty of Agriculture, Chiang Mai University
239 Huay Keaw Rd, Suthep Sub-district, Muang Chiang Mai District, Chiang Mai Province 50200, Thailand
Tel: (+66) 5394-4009; Fax: 0-5394-4666
Eakaphong Chanteung (eakapong.j[at]cmu.ac.th) — Forest Fire Protection
Phuttamont Sonthikun (circle-aod[at]hotmail.com) — Forest Fire Protection
Chiang Mai University “Hariphunchai” Centre, 205 Sri Boaban Sub-district, Muang Lamphun District, Lamphun Province 51000, Thailand
https://www.agri.cmu.ac.th/2017/webs/index_division/th/5
https://sites.google.com/view/thaiflux/home
https://hec.oou.cmu.ac.th/
Infrastructure
Tower; Electrical power: solar panel (DC); Facilities for communication: available; Accommodation: available
Research Fund
Evaluating Carbon Sink, Carbon Offsets, and Carbon Credit Sales Potential from Forestry and Green Areas in the Chiang Mai University Hariphunchai Education Centre Area, Lamphun Province Project (2023–2026), financed by Chiang Mai University, Thailand
Project ID: M69IN00123 under topic “The Knowledge Park on Climate Change in Protected Area “Hariphunchai” Lamphun and Adjacent Areas for Plant Genetic Conservation” (2027–2029), financed by Chiang Mai University, Thailand
Calibration Information
Open-path analyzers were calibrated approximately every year with standard CO2 gases.