FSF: Fenglin Solar Photovoltaic Farm Site

FSF site photos

General site details

Site nameFenglin Solar Photovoltaic Farm Site
AsiaFlux site codeFSF
LocationFenglin Township, Hualien
Position23.7969 N, 121.489 E
Elevation101 m above sea level
Slope
Terrain typeFlat
Area66 ha
Fetch23-156 m
ClimateCfa
Mean annual air temperature23.6 degC (2023-2024)
Mean annual precipitation2199 mm (2023-2024)
Vegetation typeSoil beneath the solar panels is covered with low-growing herbaceous plant, while small or individual bushes are positioned near the panel edges.
Dominant Species (Overstory)NA
Dominant Species (Understory)
Canopy height2 m (solar panels)
Age
LAI
Soil typeCompacted soil converted from Typic Dystrudepts

Observation

Eddy Covariance method (CO2)

SystemOpen-path
Wind speedThree-dimensional sonic anemometer-thermometer (CSAT3, Campbell Scientific)
Air temperatureThree-dimensional sonic anemometer-thermometer (CSAT3, Campbell Scientific)
Water vaporOpen-path CO2/H2O analyzer (LI-7500DS, LI-COR Environmental)
CO2Open-path CO2/H2O analyzer (LI-7500DS, LI-COR Environmental)
Measurement height4.95 m
Sampling frequency10 Hz
Averaging time30 min
Data loggerSmartflux 3 (LI-COR Environmental)
Data storageUSB flash memory
Original dataRaw data

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation(incoming) 3.1 m Pyranometer (NR01 4-component net radiometer, Hukseflux)
Global solar radiation (outgoing) 3.1 m Pyranometer (NR01 4-component net radiometer, Hukseflux)
Long-wave radiation(incoming) 3.1 m Pyranometer (NR01 4-component net radiometer, Hukseflux)
Long-wave radiation(outgoing) 3.1 m Pyranometer (NR01 4-component net radiometer, Hukseflux)
Net radiation 3.1 m NR01 4-component net radiometer (Hukseflux)
PPFD (incoming) 3.1 m Quantum sensor (LI-190S, LI-COR Environmental)
Air temperature 2.4 m Platinum resistance thermometer and capacitive hygrometer (HMP155, Vaisala)
Humidity 2.4 m Platinum resistance thermometer and capacitive hygrometer (HMP155, Vaisala)
Soil temperature 0.10 m Acclima True TDR-315H (Acclima)
Soil heat flux 0.10 m Heat flux plate (HFP01sc, HukseFlux)
Soil water content 0.10 m Acclima True TDR-315H (Acclima)
Wind speed 5.0 m Wind Monitor (Wind Monitor 05305, R.M. Young)
Wind direction 5.0 m Wind Monitor (Wind Monitor 05305, R.M. Young)
Barometric pressure 1.0 m Barometer (092 Barometer Pressure Sensor, Met-One Inst.)
CO2 concentration 4.95 m Open-path CO2/H2O analyzer (LI-7500DS, LI-COR Environmental)
Precipitation 0.5 m TK-1 Rain gauge (Takeda)

Soil respiration

Measurement method Chamber method
IRGA LI-7810 CH4/CO2/H2O Trace Gas Analyzer (LI-COR Environmental)
Chamber type 8200-01 Soil Gas Flux Survey Chamber (LI-COR Environmental)
Chamber size 20 cm in diameter
Chamber size 20 cm in diameter
Number of chambers 1
Measuring intervals Monthly from March 2022 to February 2024
Is the ground covered by snow in winter? (if yes, how about the measurement in winter? No
Original data (Raw data or statistics) Raw data
Temperature and air pressure correction (if done, which temperature was used?) No

Fluxes of non-CO2 gases

Gas CH4
Method Eddy covariance method (LI-7700, LI-COR Environmental)
Measurement height 5.0 m
Data logger Smartflux 3 (LI-COR Environmental)
Data storage USB flash memory
Original data (Raw data or statistics) Raw data (2023/01-12)

Other

Ecological investigation Vegetation composition, Soundscape, Camera traps for animals

Observation Period and Data Availability

Measurement PeriodJanuary 2023 to present
Measurement FrequencyContinuous
Data Availability

Contact

Shih-Chieh Chang (scchang [at] gms.ndhu.edu.tw)
Department of Natural Resources and Environmental Studies,
College of Environmental Studies and Oceanography,
National Dong Hwa University
No.1, Sec.2, Da Hsueh Rd., Shoufeng, Haulien 97401, Taiwan.
Tel: +886-3-890-3275

Cheng-Wei Lai (cwlai [at] gms.ndhu.edu.tw)
Department of Natural Resources and Environmental Studies,
College of Environmental Studies and Oceanography,
National Dong Hwa University
No.1, Sec.2, Da Hsueh Rd., Shoufeng, Haulien 97401, Taiwan.
Tel: +886-3-890-3270

Infrastructure

Tower, Electrical power (AC), Facilities for communication (4G LTE)

Research Fund

(1) Grant-in-Aid for Scientific Research (Nos.113-2621-M-259-003,
112-2621-M-259-016, 111-2621-M-259-004) from the National Science and
Technology Council, Taiwan (2022-2025)
(2) Grant-in-Aid for Scientific Research (Nos. 114A601 and 112A622) from Sheng-Feng
Power, Taiwan (2023-2025)
(3) Grant-in-Aid for Scientific Research (Nos. 112-2740-M-259-002 and
113-2740-M-259-003) from the National Science and Technology Council, Taiwan
(2023-2025)
(4) Grant-in-Aid for Scientific Research (Nos. 112-2740-M001-007 and
113-2740-M001-006) from the National Science and Technology Council, Taiwan
(2023-2025)

Calibration Information

Calibration of open-path analyzer approximately every 1.5-2 years with standard CO2 gas and a dew point generator (LI610, LI-COR Environmental)