CMC: Cermat Ceria

CMC site photos

General site details

Site name Cermat Ceria
AsiaFlux site code CMC
LocationSri Aman, Sarawak
Position 01º24'01.6”N, 111º23'54.0”E
Elevation 20.11 m
Slope-
Terrain type Almost flat
Area1020 ha
Fetch1600 m (max)
Climate Tropical rainforest climate (moderately hot - very humid - receives substantial rainfall (Af))
Mean annual air temperature 26.0 C
Mean annual precipitation3158 mm
Vegetation typePadang Paya Swamp Forest
Dominant Species (Overstory) Alan (LShorea albida)
Dominant Species (Understory)
Canopy height 25 m
Age
LAI
Soil type Peat soil

Observation

Eddy Covariance method (CO2)

SystemOpen-path system
Wind speed 3-dimensional sonic anemometer (CSAT3, Campbell, USA)
Air temperature 3-dimensional sonic anemometer (CSAT3, Campbell, USA)
Water vapor Open-path CO2/ H2O analyzer (LI-7500, LICOR)
CO2Open-path CO2/ H2O analyzer (LI-7500, LICOR)
Measurement height 41 m
Sampling frequency10 Hz
Averaging time 30 min
Data logger CR3000 (Campbell, USA)
Data storage CF
Original data Raw

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation(incoming) 41 m Net Radiometer (CNR4, Kipp & Zonen, The Netherlands)
Global solar radiation (outgoing) 41 m Net Radiometer (CNR4, Kipp & Zonen, The Netherlands)
Long-wave radiation(incoming) 41 m Net Radiometer (CNR4, Kipp & Zonen, The Netherlands)
Long-wave radiation(outgoing) 41 m Net Radiometer (CNR4, Kipp & Zonen, The Netherlands)
Net radiation 41 m Net Radiometer (CNR4, Kipp & Zonen, The Netherlands)
PPFD (incoming) 41 m Quantum sensor (LI-190SB or LI190SL, LI-COR, USA)
PPFD (outgoing) 41 m Quantum sensor (LI-190SB or LI190SL, LI-COR, USA)
Direct / diffuse radiation -
Direct / diffuse PPFD -
Air temperature 5, 41 m Temperature & Relative Humidity (RH) probe (CS215, Campbell, USA)
Humidity 5, 41 m Temperature & Relative Humidity (RH) probe (CS215, Campbell, USA)
Soil temperature 0.05, 0.1 m Platinum resistance thermometer (Pt100, Japan)
Soil heat flux
Soil water content 0.15, 0.3 m Soil Water Content Reflectometer (CS616)
Wind speed 41 m TDR sensor (CS616, Campbell, USA)
Wind direction 41 m TDR sensor (CS616, Campbell, USA)
Barometric pressure -
Precipitation 1 m Tipping-bucket rain gauge (TE525MM, Texas Instrument, USA)
CO2 concentration 0.5, 1, 3, 11, 21, 41 m Closed-path CO2 analyzer (LI820, LI-COR, USA)

Other

Soil respiration Closed chamber method (CO2, CH4, N2O), Measuring system: Manually Measuring intervals; Monthly
Ecological Investigations -

Observation Period and Data Availability

Measurement Period From January, 2011 to present
Measurement Frequency Continuous
Data Availability N/A

Contact

Lulie Melling (lullie_melling@yahoo.com) Tropical Peat Research Laboratory Unit, Chief Minister’s Department, Lot 6035, Kuching-Kota Samarahan Expressway, 94300 Kota Samarahan Tel:+60-82-662-495 Fax:+60-82-662-497

Lulie Melling (lullie_melling@yahoo.com) Tropical Peat Research Laboratory Unit, Chief Minister’s Department, Lot 6035, Kuching-Kota Samarahan Expressway, 94300 Kota Samarahan Tel:+60-82-662-495 Fax:+60-82-662-497

Infrastructure

Tower, Solar energy system

Research Fund

Malaysian Government, Sarawak State Government

Calibration Information

CO2 analyzers were calibrated every months using spans gases.