BDP: Bidoup forest

BDP site photos

General site details

Site nameBidoup forest
AsiaFlux site codeBDP
LocationBidoup Nui Ba National Park Da Chais village, Lac Duong districts, Lam Dong province,Vietnam
Position12°11'04.0'' N, 108°41'31.4'' E (GPS 18x LVC, Garmin, within SmartFlux2 system, LI-COR)
Elevation1498m
Slope~10°
Terrain typeHilly mountains
Areaabout 30 ha of uniform ecosystem around the tower
Fetch245 m (90%), 90 m (peak)
ClimateCf, Mild temperate, fully humid
Mean annual air temperature17.5 (2022-2023) °С
Mean annual precipitation2980 mm (2022-2023)
Vegetation typePolydominant mountain forest
Dominant Species (Overstory)Pinus dalatensis, Рinus krempfii (Pinaceae), Dacricarpus imbricatus, Dacrydium elatum (Podocarpaceae), Rhodoleia championii (Rhodoleiaceae), Schima wallichii (Theaceae), Craibiodendron stellatum (Ericaceae), Magnolia sp. (Magnoliaceae).
Dominant Species (Understory)Poilannammia costata, Pseudodissochaeta septentrionalis (Melastomataceae), Ardisia sp. (Myrsinaceae), Lasianthus spp. (Rubiaceae).
Canopy height25 m
AgePrimary forest
LAINot measured
Soil typeTopsoil 0-20 cm (black, 2.5Y 2.5/1 Munsell scale) with ferralitic soil below (light yellow-brown, 2.5Y 7/2, 7/4 — 4/4 Munsell scale)

Observation

Eddy Covariance method (CO2)

SystemEnclosed-path system (CO2 flux, latent heat flux)
Wind speedThree-dimensional sonic anemometer (WindMaster Pro, Gill inatruments)
Air temperatureThree-dimensional sonic anemometer (WindMaster Pro, Gill inatruments)
Water vaporEnclosed-path CO2/H2O analyzer (LI-7200, LI-COR)
CO2Enclosed-path CO2/H2O analyzer (LI-7200, LI-COR)
Measurement height36 m
Sampling frequency10 Hz
Averaging time30 min
Data loggerLI-7550 Analyzer Interface Unit / SmartFlux2
Data storageUSB drive, FTP upload
Original dataRaw data

Meteorology

Observation items Levels/Depth Instrument
Global solar radiation (incoming) 36m 4-component net radiometer with ventilation unit (CNR4+CNF4, K&Z)
Global solar radiation (outgoing) 36m 4-component net radiometer with ventilation unit (CNR4+CNF4, K&Z)
Long-wave radiation (incoming) 36m 4-component net radiometer with ventilation unit (CNR4+CNF4, K&Z)
Long-wave radiation (outgoing) 36m 4-component net radiometer with ventilation unit (CNR4+CNF4, K&Z)
Net radiation 36m 4-component net radiometer with ventilation unit (CNR4+CNF4, K&Z)
Air temperature 36m, 2m Platinum resistance thermometer and capacitive Hygrometer (HMP155, Vaisala)
Humidity 36m, 2m Platinum resistance thermometer and capacitive Hygrometer (HMP155, Vaisala)
Soil temperature 8 cm (six points) Thermistor (7900-180 temperature probe, LI-COR); HydraProbeII (Stevens)
Soil heat flux 5 cm Heat flux plate (HFP01, Hukseflux)
Soil water content 8 cm Coaxial Impedance Dielectric Reflectometry sensor (HydraProbeII, Stevens)
Wind speed 36m Sonic anemometer (WindMaster Pro, Gill inatruments)
Wind direction 36m Sonic anemometer (WindMaster Pro, Gill inatruments)
Barometric pressure 36m Analyser interface unit built-in barometer (LI-7550, LI-COR)
Precipitation 36m Tipping-bucket rain gauge (TE-525M, Texas Instruments)
CO2 concentration 36m Enclosed-path CO2/H2O analyzer (LI-7200, LI-COR)

Observation Period and Data Availability

Measurement PeriodJuly 2022 -- present
Measurement FrequencyContinuous
Data Availability

Contact

[PI – VN side]
Dinh Ba Duy (duydb.vrtc[at]gmail.com)
Joint Vietnam-Russia Tropical Science and Technology Research Center
Institute of Tropical Ecology
63 Nguyen Van Huyen str., Nghia Do ward, Hanoi city, 100000, Vietnam
Tel: (+8424) 38363906

[PI – RU side]
Julia Kurbatova (kurbatova.j[at]gmail.com)
A.N. Severtsov Institute of Ecology and Evolution of the Russian Academy of Sciences
V.N. Sukachev Laboratory of Biogeocenology
Leninsky Prospekt, 33
Moscow, 119071, Russia
Tel:+7(903)710-3744

[Fluxes, Meteorology, Instrumentation]
Vitaly Avilov (vitavilov[at]gmail.com)
A.N. Severtsov Institute of Ecology and Evolution of the Russian Academy of Sciences
V.N. Sukachev Laboratory of Biogeocenology Leninsky Prospekt, 33 Moscow, 119071, Russia
Tel:+7(903)262-6295

Dinh Vu Anh Tu (anhtu2893[at]gmail.com)

Natalia Myslitskaia (myslitskaya[at]gmail.com)

Fedor Amirov (amirow-fedor[at]mail.ru)

Ngo Thanh Dat (datdotq95[at]gmail.com)

Infrastructure

Tower (36m), ancillary building (2x4m), solar power, LTE communication, accomodation (2 km away)

Research Fund

Joint Vietnam-Russia Tropical Science and Technology Research Center

Calibration Information

・ LI-7200 – annual CO2/H2O zero using molecular sieve scrubber (31022 Zero Air Generator, Campbell Scientific), annual CO2 span – using reference gas (616ppm CO2 in air)
・ HMP155 – annual 2-point humidity adjustment by ~35% and ~85% points using reference capacitive hygrometer DV2-TS (Microfor, Russia), 1-point temperature adjustment using reference platinum thermometer PTSV-6-Km-3 (Microfor, Russia)
・ TE525M – annual field check using Rain Gauge Calibrator (52260, RM Young), 500ml, .50 orifice
・ CNR4 – annual field matching (+inversion test) with reference pyranometer (SR30D2, Hukseflux) and pyrgeometer (IR20, Hukseflux)
・ LI190R – annual field matching with reference quantum sensor (LI190R, LI-COR)
・ LI7550 integrated barometer – annual comparison with reference absolute pressure sensor PDE-020I-DA (Elemer, Russia)

Publication

N/A